20 approvals made in accordance to vde, ul and csa requirements three phase filters f.ll.d3 series ? sc type residential / light industrial environments high performance, slim, compact design this wide range of compact, three phase multistage filters offer a high level of attenuation performance across a broad frequency range for the suppression of inverters and power drive applications. universal voltage and technical specifications ensure the range meets the needs of world-wide power drive systems and are ideally suited for long motor cable runs. ? current ratings from 8a to 130a ? high attenuation performance ? high voltage 520vac design for worldwide applications ? multi-stage circuitry ? space saving, slim, lightweight enclosure ? safety block or cable output termination options code i r l cx cy r circ (a) (mh) (f) (nf) (m ? ) diag f.ll.d3.008a.sc. *1 8 0.5 9x1 6x110 3x0.33 + 1x0.62 a f.ll.d3.016a.sc. *1 16 0.5 9x1 6x110 3x0.33 + 1x0.62 a f.ll.d3.030a.sc. *1 30 0.5 9x1 6x110 3x0.33 + 1x0.62 a f.ll.d3.042a.sc. *1 42 0.5 9x1 6x110 3x0.33 + 1x0.62 a f.ll.d3.055a.sc. *1 55 0.27 9x2.2 6x110 3x0.33 + 1x0.62 b f.ll.d3.075a.sc.r1 75 0.27 9x2.2 6x110 3x0.33 + 1x0.62 b f.ll.d3.100a.sc.r1 100 0.27 9x2.2 6x110 3x0.33 + 1x0.62 b f.ll.d3.130a.sc.r1 130 0.27 3x1.5 + 6x3.7 6x110 3x0.33 + 1x0.62 c * = r - safety terminal block or w - output cable electrical specifications rated voltage (v r ): 520vac, 50/60 hz rated current (i r ): referred to 50 c leakage current (i l ): normal condition: <3ma fault condition: 82ma max @ 520vac 50 hz voltage test (2 s .): line to ground 3470 vdc line to line 1700 vdc climatic category: hmf (25/100/21): temperature range: -25 c to +100 c mechanical specifications manufacture: aluminium enclosure connections: r1 - safety terminal block 10mm 2 solid wire, 6mm 2 flex wire - 8a, 16a 16mm 2 solid wire, 10mm 2 flex wire - 30a, 42a 35mm 2 solid wire, 25mm 2 flex wire - 55a, 75a 50mm 2 solid wire and flex wire - 100a, 130a w1 - output cable (8a - 55a only) dimensions code 8a 16a 30a 42a 55a 75a 100a 130a a 255 305 335 329 329 329 379 439 b 126 142 150 185 185 220 220 240 c 50556070808090110 d 225 275 305 300 300 300 350 400 e 240 290 320 314 314 314 364 414 f 2530354555556580 g 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 h 300 300 400 500 500 j22233336 l 9 9 9 12 12 0 m5 m5 m5 m6 m6 m6 m10 m10 p 16 14 10 8 6 awg sizes, tri-rated cable filter range circuit diagrams a line load load load b line c line
21 -20 0 20 40 60 80 100 .01 .1 1 10 100 .15 30 mhz db 0 10 20 30 40 50 60 70 80 90 100 .01 .1 1 10 100 .15 30 mhz db 0 10 20 30 40 50 60 70 80 90 100 .01 .1 1 10 100 .15 30 mhz db 0 10 20 30 40 50 60 70 80 90 100 .01 .1 1 10 100 .15 30 mhz db 0 10 20 30 40 50 60 70 80 90 100 .01 .1 1 10 100 .15 30 mhz db 0 10 20 30 40 50 60 70 80 90 100 .01 .1 1 10 100 .15 30 mhz db 0 10 20 30 40 50 60 70 80 90 100 .01 .1 1 10 100 .15 30 mhz db 0 10 20 30 40 50 60 70 80 90 100 .01 .1 1 10 100 .15 30 mhz db dimensions (mm) and connections three phase filters f.ll.d3 series ? sc type residential / light industrial environments insertion loss (typical) ??? symmetrical (line to line) asymmetrical (line to ground) ...f.ll.d3.008a.sc.*1 ...f.ll.d3.016a.sc.*1 ...f.ll.d3.030a.sc.*1 ...f.ll.d3.042a.sc.*1 ...f.ll.d3.055a.sc.*1 ...f.ll.d3.075a.sc.*1 ...f.ll.d3.100a.sc.*1 ...f.ll.d3.130a.sc.*1 0 10 20 30 40 50 60 70 80 90 100 .01 .1 1 10 100 .15 30 mhz db
|